Mares NEMO AIR Betriebsanweisung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
Nemo Air Dive computer
16
FIG. 54
WARNING
Before closing the cover, check that
the gasket is positioned correctly in its
seat. Make sure it is perfectly clean, and
lubricate it with a thin film of silicone
grease.
NOTE
When applying the silicone grease, be
careful not to get the battery or contact
plates dirty.
NOTE
Nemo Air may show a low battery charge
after the battery has been replaced. If this
happens, run a battery check by entering
SYSTEM mode.
NOTE
Do not discard the old battery in the
environment. Mares adopts a policy of
respect for the environment, and urges
use of the appropriate separated waste
collection service.
WARNING
Do not replace the battery within the
3 minutes immediately following a dive.
Replacing the battery too soon after the
dive will result in loss of the data for that
dive. In any case, remember that replacing
the battery causes the residual nitrogen,
desaturation time and no-fly time data to
be lost. It is therefore advisable to make a
note of this information before replacing
the battery.
WARNING
Do not replace the battery between
repetitive dives.
INSTRUCTIONS FOR CONNECTING NEMO AIR
TO THE HP HOSE
Nemo Air is made up of two distinct elements:
the computer and the high-pressure hose,
which are connected to each other by means
of a quick-release coupling designed and
tested for an operating pressure of 300 bar.
The hose must be connected to the regulator’s
first stage before the latter is mounted on the
tank: if this operation is carried out when the
regulator is already assembled on the tank,
make sure that the tank valve is fully closed
and that the entire system is depressurized
by pressing the purge button on the regulator
second stage.
WARNING
Under no circumstances replace the
hose fitted on the computer with one of
a different type; consult your dealer or
Mares for information about the type of
hose to be used.
WARNING
Before pressurizing the instrument, check
that the quick coupling has been correctly
engaged.
WARNING
The Nemo Air can only be connected
and subsequently disconnected from the
high-pressure hose after depressurizing
the group. Therefore, if the computer
is assembled on the first stage of a
regulator that is already connected to a
tank, depressurize the group as described
above.
In order to connect the computer to the hose,
insert the connector attached to the hose into
the connector attached to the computer, and
then press all the way in (figure 55 and 56):
FIG. 55
FIG. 56
Do not use tools to tighten the Nemo Air
connection.
WARNING
Attempting to carry out operations in the
presence of high pressure may result in
serious injury.
Connect the threaded 7/16” UNF
terminal to a high-pressure outlet on the
regulator’s first stage (check the regulator
instruction manual to find out which are
the high pressure outlets) and tighten
(max 4-5 N.m. / 35.4-44.3 lb.in) with a
hexagon wrench (14 mm).
INSTRUCTIONS FOR ATTACHING
THE COMPASS
(OPTIONAL COMPONENT, SOLD SEPARATELY)
With reference to figure 57, the following steps
are necessary in order to attach the compass:
1. Unscrew the 6 screws that fasten the two
shells of Nemo Air.
2. Remove the bottom shell.
3. Remove the top shell.
4. Remove the top cover.
5. Fit the compass module.
6. Replace the bottom and top shells and lock
the 6 screws back down.
1
2
4
5
3
FIG. 57
TECHNICAL/FUNCTIONAL
CHARACTERISTICS
TECHNICAL FEATURES
PRESSURE GAUGE FUNCTION
The pressure gauge integrated with the
Nemo Air dive computer has been tested and
CE certified by Registered Test Center #0426 -
ITALCERT, V.le Sarca, 336 - 20126 Milan - Italy
and by - INPP – Entrée n°3 – Port de la Pointe
Rouge BP 157 -13267- Marseille – France.
The pressure gauge integrated with the
Nemo Air computer is a Category III device
as defined under European Directive 89/686/
CEE, and complies with the specifications set
out in the harmonized European Standard
EN 250/2000 for use with air compliant with
Standard EN 12021 (oxygen content of 21%).
The pressure gauge is compliant with the
specifications set forth in the European
Standard EN 13949: 2003 for use with oxygen-
rich mixtures (Nitrox).
The EC certification process and verification
of the operating performance of the pressure
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18

Kommentare zu diesen Handbüchern

Keine Kommentare